LED display common troubleshooting diagnostics

The LED electronic display is a display mode that controls semiconductor light-emitting diodes and is composed of tens of thousands--several hundreds of thousands of semiconductor light-emitting diodes. It can use different materials to produce LED pixels with different colors to display various screens for text, graphics, images, animations, quotes, videos, and video signals. It is widely used in securities trading, financial information display, and airports. Flight dynamic information display, guidance information display for the port station tourist passengers, sports venues, road traffic display, information display of the dispatching command center, postal services, telecommunications, mall shopping centers, advertising media new product display and many other types of places.

In practical applications, LED displays inevitably encounter various kinds of failures, causing inconvenience to the application of industrial users and affecting the efficiency of use. This article will summarize some of the common problems and solutions for daily LED display applications.

About the screen is not lit all kinds of situations and solutions With the long-term use of LED electronic display, there may be some failures, if the LED electronic display screen brightness problems, you can check against:

I. The whole screen is not bright (black screen)

1. Detect power supply power.

2. Check whether the communication line is connected or not. (Sync screen)

3. The sync screen detects whether the green light of the sending card and the receiving card is flashing.

4. Whether the computer monitor is protected or the display area is black or pure blue. (Sync screen)

II. Whole cell board is not bright (black screen)

1. Several consecutive boards are not bright in the horizontal direction. Check whether the cable connection between the normal unit board and the abnormal unit board is connected; or whether the chip 245 is normal.

2. After several consecutive boards do not light up, check whether the power supply of this column is normal.

III. The line on the cell board is off. Check if there is a connection between the line foot and the 4953 output pin.

2. Check 138 is normal.

3. Check 4953 whether it is hot or burned.

4. Check 4953 whether there is a high level.

5. Check whether the 138 and 4953 control pins are connected.

IV. The cell board is off Check 595 is normal.

2. Check whether the corresponding module is connected to the upper and lower modules.

3. Check 595 output pin to the module pin is connected.

V. Unit board lack of color Check the 245R.G data for output.

2. Check whether the normal 595 output pin and the abnormal 595 input pin are connected. In addition to the screen is not lit, the following are the problems that may occur in the LED electronic display and solutions 01. What could be the cause of the load?

Failure to load may be due to the following reasons: Please check against your actions according to the listed items:

A. Make sure the control system hardware is properly powered up. (+5V)

B. Check and confirm that the serial cable used to connect to the controller is a straight line, not a crossover cable.

C. Check that the serial port cable is intact and that neither end is loose or missing.

D. Compare the LED display control software with the control card of your choice to select the correct product model, the correct transmission method, the correct serial port number, the correct baud rate and correctly set the control system hardware against the dial switch diagram provided in the software. The address bit and baud rate.

E. Check if the jumper cap is loose or loose; if the jumper cap is not loose, make sure the jumper cap is in the correct direction.

F. If after the above checks and correction still occurs after loading, please use a multimeter to measure if the serial port of the connected computer or control system hardware is damaged. To confirm whether the computer manufacturer should be returned or return the control system hardware to the test.

02. What could be the cause of the lack of communication?

The reason for the failure to communicate is not the same as the reason for the failure to load. It may be due to the following reasons. Please check against the listed items and your actions:

A. Make sure the control system hardware is properly powered up. (+5V)

B. Check and confirm that the serial cable used to connect to the controller is a straight line, not a crossover cable.

C. Check that the serial port cable is intact and that neither end is loose or missing.

D. Compare the LED display control software with the control card of your choice to select the correct product model, the correct transmission method, the correct serial port number, the correct baud rate and correctly set the control system hardware against the dial switch diagram provided in the software. The address bit and baud rate.

E. Check if the jumper cap is loose or loose; if the jumper cap is not loose, make sure the jumper cap is in the correct direction.

F. If after the above checks and correction still occurs after loading, please use a multimeter to measure if the serial port of the connected computer or control system hardware is damaged. To confirm whether the computer manufacturer should be returned or return the control system hardware to the test.

03. Why does the system prompt "Please connect the LED display controller"?

Many customers and friends directly download the "LED display control system" from the "Download Center" on the company's website. After installing for 20 minutes, the message "Please connect the LED display controller" will appear. This is due to the system The reason why the open control system hardware was not detected during the test period.

At this time, please connect one end of the LED display control system hardware you purchased to the computer and the other end to the HUB distribution board. The HUB distribution board's cable socket is connected to the interface of each unit of the LED display.

After the connection is complete, you can go to the "settings" in the "setting screen parameters" set the relevant parameters, complete and then close again after opening the software, then the software will appear above the "connection is successful" words. At this point, the system has detected the display control system hardware and can be used without time constraints.

04. Why does the LED display control system hardware display a few seconds of bright lines or "screen" when it is first powered on?

After properly connecting the display controller with the computer and HUB distribution board and display, it is necessary to provide the controller with +5V power for normal operation (in this case, do not directly connect with the 220V voltage). At the moment of power-on, there will be a few seconds of bright lines or "Hua Ping" on the display screen. The bright line or "Hua Ping" is a normal test phenomenon to remind the user that the display is about to start normal work. Within 2 seconds, this phenomenon is automatically eliminated and the display goes into normal operation.

05. What does automatic or manual brightness adjustment mean?

Brightness adjustment refers to the adjustment made between the darkest and brightest display on the display. Instead of light regulation.

The automatic brightness adjustment is based on the different brightness that should appear during different time periods and is automatically adjusted by the wide LED display control system to a predetermined brightness.

Manual brightness adjustment refers to that the end user achieves a specified brightness of the LED display through the operation of the LED display control system.

06. Why doesn't the display show above when everything is normal?

If the controller settings and connection cables are properly connected, sometimes the LED display screen will show no display. Generally, it is caused by one of the following reasons. Please check:

A. LED display is powered on.

B. Whether the connection between the HUB distribution board and the display screen is reversed.

C. Whether the edited and sent program is empty.

07. The unit board appears full screen dark and dark.

A. Visually inspect the power supply cable, the 26P cable between the unit boards, and the power module indicator.

B. Use a multimeter to measure the normal voltage of the unit board, and then measure whether the voltage output of the power module is normal. If not, judge that the power module is bad.

C. Measure the power module voltage is low, adjust the fine-tuning (fine-tuning of the power module near the indicator light) to make the voltage reach the standard.

08. What causes the black screen on the LED display?

In the process of using the control system, we occasionally encounter the phenomenon of black screen LED display. The same phenomenon may be caused by various reasons, and even the darkening of the display screen may be different for different operations or different environments. For example, it may be black at the moment of power-on, or it may turn black during loading, or it may be black after sending. If you encounter this phenomenon, please note that you can refer to the following aspects to determine the "failure":

A. Please ensure that all hardware, including the control system, is properly powered on. (+5V, do not connect, connect wrong)

B. Check and re-check if the serial cable used to connect the controller is loose or missing. (If it turns black during the loading process, it may be caused by this reason, that is, it is interrupted during the communication process due to the loose communication line. Therefore, the screen should not be blacked out. Do not think that the display screen is not moving and the wire cannot be loosened. Please Hands-on inspection, this is very important for you want to quickly solve the problem.) Wen / Shenzhen LED base (WeChat public number: Shenzhen LED base)

PVC Ceiling Tiles

PVC Ceiling Tiles is new materials for wall decoration. 

Our PVC Ceiling Tiles is widely used in interior decoration like hotel, restaurant, laboratory, bathroom, home etc.

It is radiation free, water-proof, fire-proof, wear resistance (green decoration material).

Feature

1. Fireproof

PVC Ceiling Tiles is non-flammable and conforms to the national grade B1 standard (GB8624-2012 Grade B1).

2. Water-proofing and moisture-proofing

The product is allowed to long-term expose to moist environment.

3. Easy to install

PVC Ceiling Tiles is easy to cut, saw nail, stick. it has a smooth finish one side that can be taped and jointed ready for decoration including wallpapering, painting, texture coat and veneer, and a rougher side for tiling.

5. Environment

PVC Ceiling Tiles does not contain any organic solvents, formaldehyde, asbestos, oils or other toxic substances that can have a negative impact on the environment and waterways.


Specification size

1220mm*2440mm

Surface Finish

High UV coating

Thickness

1-9mm

Color

Customized colors

Hardness

3H-6H

Materials

PVC

Type

PVC Ceiling Tiles

Installation

Easy installation

Life Span

15 years

Place of original

China


pvc marble panel

PVC Ceiling Tiles

Pvc 3D Ceiling Tiles,Pvc Wooden Ceiling Tiles ,Pvc Marbling Ceiling Tiles,Uv Pvc Ceiling Tiles

Shandong Kingmarble Decoration Materials Co.,Ltd , https://www.pvcmarblepanel.com